Skip to main content

BigPanda Unified Data Connector

The BigPanda Unified Data Connector syncs data from your ITSM platforms to provide context and insight for the AI Incident Assistant, Incident Prevention, and AI Detection and Response. Ingested data is securely stored and made available in the IT Knowledge Graph, powering accurate answers, deep analytics and trend analysis, and advanced capabilities.

The Unified Data Connector can connect to ServiceNow and Confluence

Assistance required

Setting up a Unified Data Connector requires close coordination with the BigPanda team. Contact your BigPanda account manager if you’d like to enable this feature. 

Unified Data Connector Configuration

The unified data connector setup process is multi-step and involves close coordination with BigPanda support. Contact BigPanda support when you are ready to set up a data connector.

ServiceNow Data Connector Set Up

By default, the ServiceNow data connector syncs data from the following ServiceNow tables:

Table

Contents

change_request

Requests for system modifications

cmdb_ci

Configuration items in the CMDB

incident

Incidents

kb_knowledge

Knowledge base articles

problem

Root causes of incidents

sys_attachment

Attachment changes and metadata

sys_attachment_doc

Attachment binaries

task_ci

Task-related configuration items

change_task

Tasks for change requests

The Unified Data Connector is highly customizable and can sync additional tables.

To begin, reach out to BigPanda support and provide credentials for your ServiceNow instance.

The user account provided must have at least read permission access to all of the tables to sync from ServiceNow.

The account time zone must be set to GMT, and must have the date format set to yyyy-MM-dd in the sys_user table.

sysusertable.png

These credentials are required: 

Field

Description

Instance

The name of your ServiceNow instance. (i.e. <yourinstance>.service-now.com)

Username

Username of the account used to access ServiceNow.

Password

Password of the account used to access ServiceNow.

The BigPanda team will use your ServiceNow credential information to set up the data connector. Certain fields and options are customizable depending upon your organization’s preferences and requirements.

Provide the following information about your sync preferences to BigPanda:

Required Configuration 

Option

Description

Fields

Determine which fields you’d like to include from each ServiceNow table. You can also choose to include all fields.

Mode

Determine whether you’d like to set up an incremental or historical sync. You can also choose to do both sync modes.

Optional Configuration 

Option

Description

Related Tables

For each table, you can choose to include a related table. 

For example, if an incident has CIs, you can include the task_ci related table to collect them along with the incident.

See the Related Tables section below for a list of related tables and join fields.

Filter

You can apply query filters to specific tables to granularly choose what data is extracted. Each table’s filter is applied independently. Tables without a filter will load all records.

Filters use ServiceNow's encoded query syntax with ^ as AND and OR as OR. 

We recommend using ServiceNow's query builder to test filters before adding them to the configuration. See the ServiceNow documentation for more information. 

Start Date

If you’re setting up a historical sync, provide the date of when you’d like the sync to begin. If no start date is provided, all data will be synced.

We recommend syncing one year of data.

End Date

Used for historical syncs only. Provide an end date to backfill historical syncs.

Read Replica

ServiceNow supports read replicas through the sysparm_query_category parameter. This allows you to direct queries to specific database replicas within ServiceNow's infrastructure.

If you’d like to set this up, provide your replica name. 

Performance-Related Configuration 

Option

Description

Query Limit

The maximum number of queries that can be sent per minute. The default is 60 queries per minute.  

Rate Limit Timeout (MS)

The timeout period in milliseconds after the query limit has been reached. The default is 1000 ms (1 second).

Confluence Data Connector Set Up

The Confluence Data Connector syncs data from your Confluence pages. The data connector can be set up with both cloud and server instances of Confluence.

To begin, reach out to BigPanda support and provide credentials for your Confluence instance. The user account provided must have at least read permission access to all of the pages that will be synced from Confluence.

These credentials are required:

Field

Description

URL

The URL of your Confluence instance (https://your-domain.atlassian.net)

Username

Username of the account used to access Confluence.

Password

Password of the account used to access Confluence.

Cloud

Whether or not your instance is Confluence Cloud. (True or False)

The BigPanda team will use your Confluence credential information to set up the data connector. Certain fields and options are customizable depending upon your organization’s preferences and requirements.

Provide the following information about your sync preferences to BigPanda:

Option 

Description 

Space keys

The unique key(s) of your Confluence space(s). 

The key can be found in your Confluence URL after /spaces/ (i.e.: https://yourinstance.atlassian.net/wiki/spaces/<spacekey>/)

Mode

Determine whether you’d like to set up an incremental or historical sync. You can also choose to do both sync modes.

Start date

If you’re setting up a historical sync, provide the date of when you’d like the sync to begin.

We recommend syncing one year of data.

CQL filters (Optional)

You can use Confluence Query Language (CQL) to set up content filters. This allows you to extract only the content that matches your criteria. 

Historical Mode vs. Incremental

You can choose to set up either a historical or incremental sync for both the ServiceNow and Confluence data connectors.

Historical syncs allow you to load only data from a selected start date and after. This mode works well for one-time data loads or when you need to backfill data that was previously missed. Historical mode is the default, recommended method of syncing data. 

Historical sync

Historical syncs can take minutes or days, depending on the amount of data sent.

Incremental syncs run periodically and load all new or updated records. This mode works well for scheduled, recurring data loads. Depending on what functionality you are using within BigPanda or Biggy, your incremental sync time period may vary.

Frequently Asked Questions

General

Q: How does the Unified Data Connector protect sensitive data and PII?

A: You can create filters for your tables to ensure that sensitive data is not included in the sync. Additionally, a Data Redaction feature will soon be available that will automatically scan for PII and remove it.

Q: How long does the initial sync take?

A: It depends on the rate limit in place, the amount of data synced, and the sync start date. The initial sync can take anywhere between a few hours to multiple weeks.

Q: How often does the data sync?

A: The default sync frequency is set to 2 minutes, but it can be modified. You can set the frequency from 1 minute to 24 hours.

ServiceNow

Q: How do you ensure that APIs don’t bypass manual review or approval processes when writing back into ServiceNow (such as during incident closure), and that audit trails are preserved?

A: The Unified Data Connector does not write anything to ServiceNow. It only uses GET APIs to pull data. Just like other user activity, you can track the user activity of the Unified Data Connector user in the ServiceNow system logs.

Q: What controls are in place to ensure that ServiceNow performance is not affected by large data pulls or frequent polling?

A: The Unified Data connector has the following features in place to control and limit the number of calls and load on the server:

  • Batch size control - Larger batch sizes result in fewer overall calls to the server.

  • Max calls per minute - This setting controls the maximum number of calls sent to ServiceNow. After it reaches the maximum, it pauses for a configured amount of time.

  • Rate limits - ServiceNow blocks users who reach the rate limit. If the rate limit is reached, the Unified Data Connector waits the amount of time returned by ServiceNow in the request header before sending additional queries.

  • Incremental loads - Every incremental load starts from the state that the last load had completed.

Q: Will customizations break if ServiceNow upgrades or changes its APIs?